Features
A. Repeatable, high-power performance delivering consistent results
- Exceptional power stability as power remains stable throughout gem’s lifetime
- Tight focus and efficient fiber coupling for repeatable, consistent results
- High power on sample to optimize use in a diverse array of applications
B. Cost effective, customizable, flexible platform
- Efficient thermal management reducing cooling requirements and costs
- Available fiber coupling solutions at 70% efficiency above 500 mW, offering uniformed power at sample and increased productivity
- Customizable features delivering solution flexibility to OEM integrator
C. Ease of integration
- Compact size with high power; easy to retrofit into OEM platforms
- Simple plug and play solution increasing productivity and reducing downtime
-
Specification
Model | Ventus 532 |
Wavelength | 532 nm |
Power | 100 - 1500 mW |
Beam Diameter1 | 1.5 ± 0.1 mm |
Spatial Mode | TEM00 |
Ellipticity | <1:1.15 |
Bandwidth | 30 GHz |
Divergence | ≤0.6 mrad |
M-Squared | <1.1 |
Power Stability (RMS)2 | <0.4% |
Noise (RMS)3 | <0.15% |
Noise Bandwidth | 10 Hz - 100 MHz |
Beam Pointing Stability | <10 μrad/°C |
Polarization Ratio | >100:1 |
Polarization Direction4 | Horizontal |
Coherence Length | ~1 cm |
Beam Angle5 | <1 mrad |
Operating Temperature | 15 - 40 °C |
Weight | 0.75 kg |
Umbilical length | 1.5 m |
Additional Info. |
Cooling options available System can be modulated Vertical polarization is available on request Fiber coupling available LabView drivers available |
* Laser Quantum operates a continuous improvement programme which can result in specifications being improved without notice.
1 Beam diameter defined as the average of major and minor 1/e2 beam size measured at 25 cm from exit port, at specified power.
2 Test duration >100 hrs at constant temperature.
3 ventus 532 50 mW to 500 mW≤0.4%.
4 Vertical polarization is available upon request.
5 Tolerance relative to head orientation.
-
Dimensions(mm)
-
Power supply unit
Typical power curve of the Ventus 532 nm laser, (blue) with the corresponding noise (red)
Typical noise and power stability of the Ventus 532 nm laser over 100 hours, depicting noise ~0.06 %